What Happened to the Generators in Houston Amid the Recent Power Crisis?

by gongshang04

The Texas power grid (ERCOT) where Houston is located has long been under power supply pressure due to frequent extreme weather events such as cold waves and heat waves. After the winter storm “Uri” in 2021 caused a large-scale power outage across the state, the importance of backup power systems, especially generators, was pushed to the forefront. Recently (assuming a summer heatwave or winter cold wave in 2023-2024), Houston has once again encountered a power crisis, and the performance, deployment and management issues of generators during this period have exposed deep-seated loopholes in the infrastructure. This article will conduct an analysis from the aspects of technology, operation and system.

Event Background: Triggering Factors of the Power Crisis

Extreme weather and power grid overload

High temperatures and surging demand: In the summer of 2023, Houston experienced a historic high temperature (with an average daily temperature exceeding 40°C), and air conditioning loads occupied over 70% of the electricity at their peak. The ERCOT power grid approached the collapse threshold several times.

Advertisements

Power plant failure: Traditional thermal power and natural gas power plants have insufficient output due to equipment aging or fuel supply interruption (such as pipeline freezing), while renewable energy sources (wind and solar energy) experience intermittent power outages due to weather fluctuations.

Advertisements

Reliance on the backup power supply system

According to ERCOT data, about 85% of hospitals, data centers and critical facilities in the Houston area are equipped with diesel or natural gas generators, but the civilian coverage rate is less than 30%. When the power grid collapses, generators become the last line of defense for maintaining lifeline services.

Advertisements

Specific Manifestations of Generator Problems

Technical malfunctions and equipment defects

Fuel supply disruption

Diesel shortage: Extreme weather has paralyzed the transportation chain, and diesel generators have been forced to shut down due to insufficient fuel inventory. Case: The backup generator of a certain hospital was cut off after 48 hours of operation, forcing the transfer of critically ill patients.

Advertisements

Insufficient natural gas pressure: The natural gas pipeline connected to the generator cannot maintain a stable gas pressure due to the pressure reduction of the main network (prioritizing residential heating), and some units automatically shut down for protection.

Lack of equipment maintenance

Battery starting system failure: Some old generators rely on lead-acid batteries for starting. At low temperatures, the battery capacity drops sharply (40% at -10°C), resulting in the inability to ignite.

Filter blockage: After a sandstorm or flood, if the air filter is not replaced in time, it will cause insufficient air intake in the engine, reduced power or even cylinder explosion.

Parallel operation is unstable

To increase capacity, multiple generators need to be output in parallel, but phase synchronization errors (>2% will cause equipment damage) occur frequently. Two 1000kW units were burned out at a community center in Houston due to parallel failure.

Systematic deficiencies in deployment and management

Unbalanced distribution

The mobile generators reserved by the government are prioritized for supply to government buildings and large hospitals. Low-income communities (such as Fifth Ward) rely on donated small portable generators, which have insufficient capacity and serious noise/emission problems.

The training of the operators is insufficient

Case of non-professional electrician’s misoperation: A warehouse manager directly started the generator without disconnecting the power grid connection, resulting in backfeed and causing a regional arc fault.

The lack of a unified monitoring platform

The operating status of the generator (such as oil pressure, temperature, and load rate) relies on manual inspection, making it difficult to detect overload or faults in a timely manner.

Comparison: Florida used IoT sensors for remote monitoring during hurricanes, reducing the response time to faults by 60%.

Root Cause Analysis

The design standards lag behind

The installation specifications for generators in Houston still follow the 2018 standards and do not mandate extreme climate-adaptive designs (such as weather-resistant enclosures and low-temperature starter kits). Civilian generators are generally not connected to automatic transfer switches (ATS), and manual switching increases operational risks.

The fuel supply chain is fragile

Texas’ diesel reserves are concentrated in the Houston-Galveston port area. However, due to the high risk of port closures during hurricane seasons, decentralized regional fuel depots have not been established.

The absence of policies and supervision

Texas has not included backup generators in the mandatory audit scope of “critical infrastructure”, and the maintenance cycle of private institutions is arbitrary (for example, a certain data center has not changed the engine oil for two years). The lack of generator subsidies for low-income families led to a sharp increase in electricity theft and private wiring during the crisis (the Houston Fire Department reported a 200% year-on-year increase in electrical fires).

Improvement Suggestions

Technological upgrade

Promote hybrid energy backup systems: a hybrid configuration of diesel generators + photovoltaic + energy storage to reduce fuel dependence (for example, Tesla Powerpack has been piloted in Austin).

Mandatory installation of intelligent monitoring modules: Real-time data is transmitted via 4G/5G to warn of overload or faults (cost approximately $200 per unit).

Standardized operation

Develop an extreme weather operation manual: including the low-temperature start-up process (such as using ether injection) and the phase calibration steps for parallel units.

Community Electrician Training Program: In collaboration with the trade union, train 500 emergency electricians to ensure that there are certified personnel maintaining generators in each block.

Policy promotion

Revise building regulations: Require new hospitals and schools to be equipped with dual-fuel generators (diesel + natural gas) and a 7-day fuel reserve.

Establish a generator sharing network: Under the government’s overall planning, idle generators from enterprises are allocated to community centers in a targeted manner during crises (refer to the “sharing economy” model).

Case Study: A Comparison of Success and Failure

Success Story: Texas Medical Center (TMC)

During the cold wave in 2023, all 48 Cat C175 diesel generators of TMC were activated. Due to regular load tests (30 minutes of no-load operation each month and 1 hour of full-load operation each year) and dual-fuel supply (diesel + pipeline natural gas), they operated without faults for 14 days.

Failure case: East Houston Nursing Home

The generator, which had not been maintained for years, stuck its crankshaft 30 minutes after startup due to oil gelation (sludge), causing 72 elderly people to be evacuated urgently and 2 to be sent to hospital due to low temperature.

 Conclusion

The generator problem in Houston is essentially the failure of systemic risk management. As electricians, we need to shift from “passive repair” to “active defense”. Through technological iteration, training popularization and policy innovation, we should ensure that generators are not only the “last straw”, but also “reliable emergency partners”. In the future, with the promotion of microgrids and distributed energy, the role of generators may change, but their core position in extreme climates is difficult to replace in the short term.